Monitoring Plan Details - Temperature Monitoring

This feature lets you configure temperature reporting for a monitoring plan. Click edit in the upper right corner to change settings. You must select a sensor to monitor to see the configuration settings. When you're finished configuring temperature monitoring, click save in the upper right corner to save your changes.

Temperature Set Point
The operating temperature on the refrigerated unit that the driver sets.
Sensor to Monitor
From the drop-down list, select the default sensor to be tested against the target temperature. Options are: Return Air, Supply Air, or Return & Supply Air.
Acceptable Tolerance From Set Point
Type the temperature range above and below the temperature set point to be considered in-range (normal).
Verify Temperature Normal After
From the drop-down list, select the amount of time a temperature must return to the relative temperature range after an alarm before the alarm is turned off.
Verify Temperature Out-of-Range After
From the drop-down list, select the amount of time that the temperature can be out of range before the terminal generates an alarm.
Suspend Verification After Defrost For
From the drop-down list, select the amount of time, after a defrost cycle, that the temperature can be out of range before the terminal generates an alarm.
Temperature Event Action
From the drop-down list, select the action that you want to perform when an out-of-range/in-range event occurs:
  • Ignore-no action
  • Send with next message-send the message the next time the terminal sends a scheduled message, such as a status report
  • Send immediately-send the event as soon as it is detected
  • Send immediately and stay awake-send the event as soon as it is detected and stay powered up (awake) until the stay awake interval is reached